24

About Your System

E1210 CMOS Batt

CMOS battery is missing,

or the voltage is out of

acceptable range.

See "Troubleshooting the

System Battery" on

page 136.

E1211 ROMB Batt

RAID battery is either

missing, bad, or unable to

recharge due to thermal

issues.

Reseat the RAID battery

connector. See "Installing a

RAID Battery" on page 84,

and "Troubleshooting the

System Battery" on

page 136.

E1229 CPU # VCORE

Processor # VCORE

voltage regulator has failed.

See "Getting Help" on

page 165.

E1310 RPM Fan ##

RPM of specified cooling

fan is out of acceptable

operating range.

See "Troubleshooting

System Cooling" on

page 138.

E1313 Fan

Redundancy

The system is no longer

fan-redundant. Another

fan failure will put the

system at risk of

overheating.

Check control panel LCD

for additional scrolling

messages. See

"Troubleshooting System

Cooling" on page 138.

E1410 CPU # IERR

Specified microprocessor is

reporting an internal error.

See your system’s

Information Update Tech

Sheet located on

support.dell.com for the

most current system

information. If problem

persists, see "Getting Help"

on page 165.

Table 1-5. LCD Status Messages

Code

Test

Causes

Corrective Actions