Dell PowerEdge R900 User Manual

Page 29

Advertising
background image

About Your System

29

E1811 HDD ## Rbld

Abrt

The specified hard drive

has experienced a rebuild

abort.

See "Troubleshooting a

Hard Drive" on page 142. If

the problem persists, see

your RAID

documentation.

E1812 HDD ##

Removed

The specified hard drive

has been removed from the

system.

Information only.

E1913 CPU &

Firmware
Mismatch

The BMC firmware does

not support the processor.

Update to the latest BMC

firmware. See the

BMC

User’s Guide

for more

information on setup and

use of BMC.

E1A14 SAS Cable A

SAS cable A is missing or
bad.

Reseat the cable. If

problem persists, replace

cable. See "SAS Controller

Card" on page 78.

E1A15 SAS Cable B

SAS cable B is missing or
bad.

Reseat the cable. If

problem persists, replace

cable. See "SAS Controller

Card" on page 78.

E2010 No Memory

No memory is installed in

the system.

Install memory. See

"General Memory Module

Installation Guidelines" on

page 92.

E2011 Mem Config

Error

Memory detected, but is

not configurable. Error

detected during memory

configuration.

See "Troubleshooting

System Memory" on

page 139.

E2012 Unusable

Memory

Memory is configured, but

not usable. Memory

subsystem failure.

See "Troubleshooting

System Memory" on

page 139.

E2013 Shadow BIOS

Fail

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

System Memory" on

page 139.

Table 1-5. LCD Status Messages

Code

Test

Causes

Corrective Actions

Advertising