Dell PowerEdge R900 User Manual

Page 32

Advertising
background image

32

About Your System

E2112 Mem Spare

Crd # DIMM
##

The system BIOS has

spared the memory

because it has determined

that the memory had too

many errors. "## & ##"

represents the DIMM pair

implicated by the BIOS. If

no memory card is present,

the "Crd #" string is left

out of the message.

See "Troubleshooting

System Memory" on

page 139.

E2113 Mem Mirror

Crd # DIMM
## & ##

The system BIOS has

disabled memory mirroring

because it has determined

that one half of the mirror

has had too many errors.

"## & ##" represents the

DIMM pair implicated by

the BIOS. If no memory

card is present, the "Crd #"

string is left out of the

message.

See "Troubleshooting

System Memory" on

page 139.

E2118 Fatal NB

Mem CRC

One of the connections in

the Fully Buffered DIMM

(FBDIMM) memory

subsystem link on the

Northbound side has

failed.

See "Troubleshooting

System Memory" on

page 139.

E2119 Fatal SB

Mem CRC

One of the connections in

the FBDIMM memory

subsystem link on the

Southbound side has

failed.

See "Troubleshooting

System Memory" on

page 139.

I1910 Intrusion

System cover has been

removed.

Information only.

Table 1-5. LCD Status Messages