Cleveland range, inc, Vi. steamcub, Start up, operation, maintenance instructions – Cleveland Range 1SCE User Manual

Page 9: Start up instructions, Operation instructions

Advertising
background image

Cleveland Range, Inc.

1333 East 179

th

St., Cleveland Ohio, U.S.A. 44110

Ph: 1-216-481-4900 Fx: 1-216-481-3782

Visit our Web Site at www.clevelandrange.com

VI. SteamCub

®

Start Up, Operation, Maintenance Instructions

Start Up Instructions:

1. Make sure the unit is level before start-up and operation.
2. Open compartment door and pour 1.5 gallons (5.7 liters) of fresh water into bottom

of the cooking compartment.

• Make sure drain valve is closed.

3. Turn main power switch “ON”.

• When power is turned “ON”, unit will automatically preheat and then go into

the “Steam & Hold “ mode when temperature is reached (about 10 minutes).

• Display will read “Cool” until preheat temperature is reached (205°F-96°C)

• “Heat-On” LED indicator will illuminate when the heating elements are

activated.

4. Allow to preheat for 10 minutes. Unit is now ready for operation.

* Note; only use the timer when in the “Steam & Hold” Mode.

Operation Instructions:

1. Select desired cooking mode.

• “Constant Steam”-Continuous steaming, no timer setting necessary.

Display will signal “Cont” when using this mode.

• “Steam & Hold”

• Set desired cooking time. (Steam & Hold Only)

• 10 minute, 1 minute or 10 seconds intervals

• Push the “Start” button to begin operation.

*Note: Hold the push buttons for 3 seconds when starting, stopping or changing
cooking modes and times.

• “Hold Only” – Preset holding temperature at 160

°

F, 71

°

C. Display will signal

“Hold” when using this mode. No timer setting necessary

* Low Water Indicator: The Display will flash “add H2O” followed by a loud
continuous beep. Add enough water without overflowing over the front of the
compartment.

Advertising