Troubleshooting chart – Campbell Hausfeld GN3565V User Manual

Page 3

Advertising
background image

3

Operating Instructions

Alternator field is not energized

Low output voltage with no load

High output voltage with no load

Low output voltage under load

Erratic output voltage

Noisy operation

1. Engine speed is too slow
2. Open, shorted, or incorrect wiring

3. Faulty capacitor
4. Open or shorted field windings

5. Open diodes

1. Engine speed is too slow
2. Open diodes
3. Faulty capacitor
4. Open or shorted field windings

1. Faulty capacitor
2. Engine speed is too fast

1. Open diode
2. Engine speed too slow at full load
3. Excessive load applied

1. Unbalanced engine
2. Dirty, corroded, or loose wiring

connection

3. Unstable load applied

1. Loose generator or engine bolt
2. Short circuit in generator field or load

3. Faulty bearing

1. Adjust engine speed ✽
2. Referring to the wiring diagram, clean

and reconnect all wiring ✽

3. Replace capacitor ✽
4. Test winding resistance, replace field

winding if necessary ✽

5. Test diodes, replace if necessary ✽

1. Adjust engine speed ✽
2. Test diodes, replace if necessary ✽
3. Replace capacitor ✽
4. Test winding resistance, replace field

winding if necessary ✽

1. Replace capacitor ✽
2. Adjust engine speed ✽

1. Test diodes, replace if necessary ✽
2. Adjust engine speed ✽
3. Reduce the applied load

1. Refer to engine manual
2. Referring to the wiring diagram, clean

and reconnect all wiring ✽

3. Remove all loads, then apply each one

individually to determine which one is
causing erratic function

1. Tighten all mountings
2. Test winding resistance, replace field

winding if necessary✽
Test load devices for shorts. Replace
defective load device.

3. Replace bearing

These diagnostic and repair procedures should be performed by an authorized service center.

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Fig. 4 - Wiring Diagram for GN2560V and GN2563V

GN2560V, GN2563V, GN3560V and GN3565V

Rotor

Stator

Ground

Main Winding
120V

Excitation
Winding

Capacitor

Plug

Circuit Breaker

120V Duplex Receptacle
NEMA 5-15R

1

2

3

4

Main Winding
120V

G

W

BK

BK

W

Advertising
This manual is related to the following products: