Carrier WEATHERMAKERTM TWO-SPEED 38TDB User Manual

Page 6

Advertising
background image

O/W2

W/W1

Y1/W2

G

R

THERMIDISTAT

CONTROL

MODEL RH

VARIABLE-SPEED

CONDENSING

FURNACE

TWO-SPEED

AIR CONDITIONER

W/W1

G

Y/Y2

C

Y2

R

Y1

C

DHUM

HUM

B

S1

S2

W2

R

C

HEAT STAGE 1

COOL STAGE 1

COOL STAGE 2

HEAT STAGE 2

FAN

24 VAC HOT

24 VAC COMM

DEHUMIDIFY

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTION

Y/Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

HUM

DEHUM

DE

JUMPER

See notes 1, 2, 3, 6, 8, 10, and 12

A01495

R

Y/Y2

R

Y2

C

C

C

R

Y1

NON-PROGRAMMABLE

THERMOSTAT

MODEL 2S

FK4C, FV4A

OR 40FK

FAN COIL

TWO-SPEED

AIR CONDITIONER

J1 JUMPER

REMOVE
J2 JUMPER
FOR HEAT
STAGING

G

G

Y/Y2

DH

W/W1

W1

Y1

O/W2

Y1

O

W2

B

S1

S2

24 VAC HOT

24 VAC COMM

FAN

COOL STAGE 2

HEAT STAGE 1

HEAT STAGE 2

COOL STAGE 1

N/A

OUTDOOR

SENSOR

CONNECTION

See notes 1, 2, 3, 4, and 7

A01496

O/ W2

W/W1

Y1/W2

G

R

THERMIDISTAT

CONTROL

MODEL RH

SINGLE-STAGE

FURNACE

TWO-SPEED

AIR CONDITIONER

W

G

Y

C

Y2

R

Y1

C

DHUM

HUM

B

S1

S2

R

C

HEAT STAGE 1

COOL STAGE 2

COOL STAGE 1

N/A

FAN

24 VAC HOT

24 VAC COMM

N/A

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTION

Y/Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

See notes 1, 2, 3, 6, and 8

A01497

O/W2

W/ W1

Y1/W2

G

R

THERMIDISTAT

CONTROL

MODEL RH

TWO-STAGE

FURNACE
WITH PSC

BLOWER MOTOR

TWO-SPEED

AIR CONDITIONER

W/W1

G

Y/Y2

C

Y2

R

Y1

C

DHUM

HUM

B

S1

S2

W2

R

C

HEAT STAGE 1

COOL STAGE 1

COOL STAGE 2

HEAT STAGE 2

FAN

24 VAC HOT

24 VAC COMM

N/A

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTION

Y/ Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

See notes 1, 2, 3, 6, 8, and 10

A01498

O/W2

W/ W1

Y1/W2

G

R

THERMIDISTAT

CONTROL

MODEL RH

FURNACE
BOARD

AFS
BOARD

TWO-SPEED

AIR CONDITIONER

VARIABLE SPEED

80% NON-CONDENSING FURNACE

W/W1

G

Y/Y2

C

Y2

Y1

C

DHUM

HUM

B

S1

S2

R

W2

O

Y1

R

COM

HUM

PL9-10

DEHUM

HEAT STAGE 1

COOL STAGE 2

COOL STAGE 1

HEAT STAGE 2

FAN

24 VAC HOT

24 VAC COM

DEHUMIDIFY

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTIONS

Y/ Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

See notes 1, 2, 3, 6, 8, 10, and 11

A01499

24 VAC HOT

24 VAC COMM

HEAT STAGE 1

COOL STAGE 2

FAN

R

C

G

W/W1

Y/Y2

R

C

N/A

COOL STAGE 1

N/A

OUTDOOR

SENSOR

CONNECTION

Y1

B

S1

S2

C

NON-PROGRAMMABLE

THERMOSTAT

MODEL 2S

SINGLE-STAGE

FURNACE

TWO-SPEED

AIR CONDITIONER

G

O/W2

W

R

Y

Y2

Y1

See notes 1, 2, 3, and 5

A01500

Fig. 11—Typical 24V Wiring Diagram

6

Advertising