Installation step 6 install the door control, Warning caution warning warning, Installation step 6 – Chamberlain 2500B User Manual

Page 14: Install the door control

Advertising
background image

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet, and away
from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door
travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

Bell Wire

Terminal
Screws

Bottom Mounting Hole

Top Mounting Hole

Red

Grey

White

To release wire, push in
tab with screwdriver tip

Door Control
Connections

7/16"

Strip wire 7/16"

14

LOCK

LIGHT

Figure 4

REMOVE COVER

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from moving parts of the door and
door hardware. The installation surface must be
smooth and flat. If installing into drywall (Figure 1),
drill 5/32" holes and use anchors provided. For
pre-wired installations (as in new home construction),
it may be mounted to a single gang box (Figure 2).
NOTE: After installation, a green or amber indicator
light behind the cover will indicate proper connection.
If not lit, the Lock and Light features will not function
(reverse wires to correct).

1. Strip 7/16" of insulation from one end of bell wire

and connect to the two screw terminals on back of
door control by color: white wire to WHT and
white/red wire to the RED (Figure 3).

2. Remove white cover by gently prying on a side

corner near the top of the cover with a small flat
head screwdriver (Figure 4). Fasten with
6ABx1-1/4" self-tapping screws (drywall installation)
or 6-32x1" machine screws (into gang box) as
follows:
• Drill and install bottom screw, allowing 1/8" to

protrude above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Install top screw with care to avoid cracking plastic

housing. Do not overtighten.

• Insert bottom tabs and snap on cover. (To remove

cover after mounting, gently pry on a side corner
near the top of the white cover with paper clip or
small flat head screwdriver.)

NOTE: The push bar may stick if the door control is
not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws or relocate the door control to a
smoother surface.

3. (Standard installation only) Run bell wire up wall

and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.

4. Strip 7/16" of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red (Figure 5).

5. Use tacks or staples to permanently attach

entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.

NOTE: DO NOT connect the power and operate
the opener at this time. The trolley will travel to the
full open position but will not return to the close
position until the sensor beam is connected and
properly aligned. See Safety Reversing Sensor
Instructions beginning on page 17.

Figure 2

To Replace
Insert Bottom Tabs First

PRE-WIRED
INSTALLATION

LOCK

LIGHT

LOCK

LIGHT

To Replace
Insert Bottom Tabs First

Figure 1

STANDARD
INSTALLATION

24 Volt
2-Conductor
Bell Wire in
Gang Box

Figure 3

MULTI-FUNCTION
DOOR CONTROL (BACK)

Figure 5

WARNING

CAUTION

WARNING

WARNING

Drywall Anchors

Insulated
Staples

Screw 6ABx1-1/4"
(std installation)

Screw 6-32x1"
(pre-wired)

HARDWARE SHOWN ACTUAL SIZE

Advertising