19

Invisible Light Beam
Protection Area

Sensor

Sensor

Bell Wire

Bell Wire

Finished
Ceiling

Quick-Connect Terminals

Strip wire 7/16"

7/16"

Sensor
Connections

Connect Wire to
Quick-Connect Terminals

White/black
wire

White
wire

Red

Grey

White

Carriage Bolt
1/4"-20x1/2"

Lens

Wing Nut

Figure 4

Figure 5

MOUNTING AND WIRING THE SAFETY SENSORS
• Slide a 1/4"-20x1/2" carriage bolt head into the slot

on each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed
by a bracket extension (Figure 4).

• Finger tighten the wing nuts.
Run the wires from both sensors to the opener. Use

insulated staples to secure wire to wall and ceiling.

• Strip 7/16" of insulation from each set of wires.

Separate white and white/black wires sufficiently to
connect to the opener quick-connect terminals: white
to white and white/black to grey (Figure 5).

ALIGNING THE SAFETY SENSORS
Plug in the opener. The indicator lights in both the

sending and receiving eyes will glow steadily if
wiring connections and alignment are correct.

The sending eye orange indicator light will glow
regardless of alignment or obstruction. If the green
indicator light in the receiving eye is off, dim, or
flickering (and the invisible light beam path is not
obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust,

aiming directly at the receiving eye. Lock in place.

• Loosen the receiving eye wing nut and adjust sensor

until it receives the sender’s beam. When the green
indicator light glows steadily, tighten the wing nut.

TROUBLESHOOTING THE SAFETY SENSORS
1. If the sending eye indicator light does not glow

steadily

after installation, check for:

• Electric power to the opener.
• A short in the white or white/black wires. These

can occur at staples, or at opener connections.

• Incorrect wiring between sensors and opener.
• A broken wire.

2. If the sending eye indicator light glows steadily but

the receiving eye indicator light doesn't:

• Check alignment.
• Check for an open wire to the receiving eye.

3. If the receiving eye indicator light is dim, realign

either sensor.

NOTE: When the invisible beam path is obstructed
or misaligned while the door is closing, the door will
reverse. If the door is already open, it will not close.
The opener lights will blink 10 times. (If bulbs are not
installed, 10 clicks can be heard.) See page 17.