INSTALLATION STEP 6

Install the Control Console

Locate control console within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, away from moving parts of door and door
hardware. If installing into drywall, drill 5/32" holes and
use the anchors provided. For pre-wired installations
(as in new home construction), it may be mounted to a
single gang box (Figure 2).

1. Strip 7/16" (11 mm) of insulation from one end of bell

wire and connect to the two screw terminals on back of
control console by color: white wire to 2 and white/red
wire to the 1.

2. Remove cover by gently prying at slot in top of the

cover with a small flat head screwdriver. Fasten with
6ABx1-1/4" self-tapping screws (drywall installation) or
6-32x1" machine screws (into gang box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to protrude

above wall surface.

• Position bottom of control console on screw head

and slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid cracking

plastic housing. Do not overtighten.

Insert top tabs and snap on cover.

3. (For standard installation only) Run bell wire up wall

and across ceiling to motor unit. Use insulated staples
to secure wire in several places. Do not pierce wire
with a staple, creating a short or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red.

5. Position the antenna wire as shown.

6. Use tacks or staples to permanently attach entrapment

warning label to wall near control console, and manual

release/safety reverse test label in a prominent
location on inside of garage door.

NOTE: DO NOT connect power and operate opener at
this time. The troliey wili travei to the fuil open position
but wilt not return to the close position until the sensor
beam is connected and properly aligned.

AA WARNING

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Disconnect ALL electric and battery power BEFORE

performing ANY service or maintenance.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install control console within sight of garage door, out of

reach of children at a minimum height of 5 feet (1.5 m), and

away from ALL moving parts of door.

• NEVER permit children to operate or play with control

console push buttons or remote controls.

• Activate door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

Outside Keylock Accessory Connections

To opener quick-connect terminals: white to white;
white/red to red.

HARDWARE SHOWN ACTUAL SIZE

a

|i|i|i|i|i|i|i|i|i|i|i|iT>

Screw 6ABx1-1/4‘
Control Panel (std installation)

IIIIIIIIIIIIIIIIIIH1

Screw 6-32x1"
Control Panel (pre-wired)

Insulated
Staples

Drywall Anchors

Figure 1

REMOVE & REPLACE COVER

To Replace

Insert Top

Tabs First

Figure 2

PRE-WIRED INSTALLATION

Push Bar Cover

24 Volt Bell Wire

Controi Console Connections

Strip wire 7/16“ (11 mm)

C^r'ie"

(11

mmi>

(BACK VIEW)

17