The SCSI lnterfa<e

Chapter 3

If switch #4 is in the ON position, Coolscan is internally terminated. If switch #4

is in the OFF position (the factory default setting), Coolscan is «or internally terminat­

ed. These two settings are shown in Figure 3.4 above.

SCSI Cables

There are three basic types of SCSI cables that can be used with Coolscan. These

are all 50 conductor cables, i.e. they have 50 contacts, or ‘pins.’ These three cables are

described below.

If you are installing an LS-10, please proceed to the section “SCSI Cables

Used With the LS-10.”

SCSI Cables Used With the LS-10E

Two different types of SCSI connectors exist on PC computers. The first is a 25-

pin DB25 type connector, and the second is a Centronics 50-pin type connector. The

SCSI cable provided with your Coolscan External model has one of each type connector

on opposite ends, as shown in Figure 3.5a. This cable is used for the default configura­

tion of Coolscan, which is making the scanner the last device on the SCSI bus.

Figure 3.5

SCSI external cables, a) The 25-pin DB-25 to Centronics 50-pin cable, (b) The

Centronics 50-pin to Centronics 50-pin cable.

If you plan on placing Coolscan in the middle of the SCSI chain you will need a

Centronics 50-pin to Centronics 50-pin SCSI cable, as shown in Figure 3.5b. This

cable is not supplied with Coolscan.

SCSI cables should never be connected or disconnected while the SCSI device or

the computer is powered on. Such action can damage the SCSI controller card.