Additional Features

Drain Pipe

In humid weather, excess water may

cause the Base Pan to overflow. To
drain the water, remove the Drain Cap
and secure the Drain Pipe to the rear

hole of the Base Pan.
Press the drain pipe into the hole by

pushing down and away from the fins

to avoid injury.

This air conditioner is equipped with a
stinger fan. (See drawing, below.)
The fan has an outer ring that runs in

the water that collects in the base pan

if it gets deep. That condensate is then
picked up by the fan and expelled

through the condenser, making the air
conditioner more efficient.

CAUTIO N: Be careful w hen inserting the drain pipe. Push aw ay from

I the sharp fin area to avoid slipping injuring yourself.

Rem oval From W indow

Turn the air conditioner off, disconnect the power cord, remove the L bracket, the
screws and Support Bracket installed through the top and bottom of the guide

panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip

on the air conditioner, raise the sash, and carefully tilt the air conditioner backward,
draining any condensate. Lift the air conditioner from the window and remove the
sash seal from between the windows.

Be sure to drain ALL condensate from the air conditioner. If you don't, it could run

out while you carry the unit, making a mess and creating a slipping hazard. This
simple step will save you much cleaning and make a safer work environment.