1 safety notices, 2 fault indications, 3 causes and rectification of faults – CASO Germany EMCG 34 PRO User Manual

Page 81: Attention

Advertising
background image

caso EMCG 34 PRO

81

15.1 Safety notices

Attention

► Only qualified electricians, who have been trained by the manufacturer, may carry out

any repairs on electrical equipment.

► Improperly performed repairs can cause considerable dangers for the user and

damages to the device.

15.2 Fault indications

In the event of a fault, an error code will appear in the display; it describes the

cause of the fault.

Error code

Description

E-1

Excessive temperature within cooking chamber

The overheating cut-out terminated the current program at a cooking chamber
temperature of 230°C .

Press the Pause/Cancel button to acknowledge this fault.

The device can be re-activated after the cool down phase.

E-3

Sensor fault

The device has detected an error on a sensor and has terminated the current
programme. Press the Pause/Cancel button to acknowledge this fault.

Please note

► If error messages continue to appear after an extended waiting period and restarting the

device, then the device will need to be sent to Customer Service to be inspected.

15.3 Causes and rectification of faults

The following table assists in localizing and rectifying minor faults.

Error

Possible cause

Action

The selected program will not
start.

Device door is not closed

Close device door

Power plug is not plugged in

Plug in mains plug!

Fuse is not activated

Activate fuse

The turntable turns jerkily.

Dirt between the turntable
and the base of cooking
camber

Remove dirt

Dirt on rolling ring

Cooking vessel too large

Use different cooking vessel

Food is not sufficiently
defrosted, warmed up or
cooked after preset time has
elapsed.

Incorrectly selected time or
power level

Re-set time and power level

Repeat process

Advertising