III.

Installation Instructions

Installation Instructions

Split System piping and wiring must be installed by a qualified Refrigeration
Technician in accordance with local and national code requirements.

Condensing Unit Installation


Indoor and Outdoor Units
 The unit is designed to operate in temperatures ranging from 0°F to 110°F. A

compressor heater (sold separately) is required for temperatures below 40°F.


Indoor Units
 Condensing units can be installed remotely from the cellar in an area protected

from direct exposure to moisture and sunlight.

 The area must have suitable ventilation to maintain an ambient temperature of

110°F or less.

 If the area does not have adequate ventilation, a vent fan should be added to

supply fresh air to the space (suggested 600CFM).

 A minimum of 12" of open air space is required in front of the condenser coils.
 Indoor units can be installed with the optional outdoor hood if additional

mechanical protection is desired.

 A minimum of 12" of open air space around the perimeter of the outdoor hood

is required.


Outdoor Units
 Condensing units must be installed with the outdoor hood if the unit will be

located outdoors.

 A minimum of 12" of open air space around the perimeter of the outdoor hood

is required.


Evaporator Unit Installation

As warm air rises to the top of the cellar, the cooling unit pulls the warm air through
the evaporator coil and removes the heat from the warm air. Once cooled, the cold
air is discharged from the front of the cooling unit and circulates through the cellar.
Therefore, we recommend mounting the evaporator as close to the ceiling as
possible inside the cellar.