System R-134a Charge Guidelines
System R-134a Charge Guidelines
Actual
Line
Length
System Charge (lbs) by Model #
(ft)
3000S/Sh 4000S/Sh
6000S
8000S
5
1.38
1.65
2.31
3.71
10
1.46
1.85
2.51
3.92
15
1.54
2.05
2.71
4.12
20
1.61
2.25
2.93
4.32
25
1.69
2.45
3.13
4.53
30
1.77
2.65
3.34
4.73
35
1.85
2.85
3.54
4.93
40
1.93
3.05
3.74
5.14
45
2.01
3.25
3.95
5.44
50
2.09
3.45
4.15
5.65
55
2.16
3.65
4.36
5.86
60
2.24
3.85
4.56
6.08
65
2.32
4.05
4.76
6.29
70
2.40
4.25
4.97
6.51
75
2.48
4.45
5.17
6.72
80
2.56
4.65
5.37
6.93
85
2.64
4.85
5.58
7.15
90
2.71
5.05
5.78
7.36
Note:
1) Actual charge may vary - follow charging instructions
detailed under Item 6 in the section titled Evacuation,
Leak Detection, and Charging (above).
2) Lines sized according to Line Sizing Chart assuming actual
line length plus 10 equivalent feet for fittings losses.