V10.14

System R-134a Charge Guidelines

System R-134a Charge Guidelines

Actual

Line

Length

System Charge (lbs) by Model #

(ft)

3000S/Sh 4000S/Sh

6000S

8000S

5

1.38

1.65

2.31

3.71

10

1.46

1.85

2.51

3.92

15

1.54

2.05

2.71

4.12

20

1.61

2.25

2.93

4.32

25

1.69

2.45

3.13

4.53

30

1.77

2.65

3.34

4.73

35

1.85

2.85

3.54

4.93

40

1.93

3.05

3.74

5.14

45

2.01

3.25

3.95

5.44

50

2.09

3.45

4.15

5.65

55

2.16

3.65

4.36

5.86

60

2.24

3.85

4.56

6.08

65

2.32

4.05

4.76

6.29

70

2.40

4.25

4.97

6.51

75

2.48

4.45

5.17

6.72

80

2.56

4.65

5.37

6.93

85

2.64

4.85

5.58

7.15

90

2.71

5.05

5.78

7.36

Note:

1) Actual charge may vary - follow charging instructions

detailed under Item 6 in the section titled Evacuation,

Leak Detection, and Charging (above).

2) Lines sized according to Line Sizing Chart assuming actual

line length plus 10 equivalent feet for fittings losses.