Power Supply Requirements

EVAPORATOR

CONDENSING UNIT

SPLIT

SYSTEM

FAN AMPS @ 115V/60HZ

POWER INPUT WATTS

UNIT AMPS @

115V/60HZ

POWER

INPUT

MODEL

MCA

HIGH

MED

LOW

HIGH

MED

LOW

MCA

LRA

WATTS

3000S/Sh

1.3

1.0

0.8

0.7

107

84

70

6.4

28.2

442

4000S/Sh

1.7

1.4

1.1

1.0

159

122

107

9.2

40.0

591

6000S

2.6

2.1

1.7

1.4

214

168

140

13.5

53.0

922

8000S

3.5

2.8

2.2

1.9

318

244

214

15.4

51.0

1028

NOTES:

SPLIT

SYSTEM

SYSTEM AMPS

POWER INPUT WATTS

MODEL

MCA

LRA

HIGH

MED

LOW

3000S/Sh

7.4

28.0

549

526

512

4000S/Sh

10.6

40.0

750

713

698

6000S

15.6

53.0

1136

1090

1062

8000S

18.2

51.0

1346

1272

1242

NOTES:

Option A: Dual Power / Valve Control

Option B: Single Power / Electronic Control

1) A 15 amp dedicated circuit breaker (non GFI) is recommended for 3000S/Sh and 4000S/Sh systems.

2) A 25 amp dedicated circuit breaker (non GFI) is recommended for 6000S and 8000S systems.

1) Separate 115V / 60HZ power supplies are required for the Evaporator and the Condensing Unit.

2) A 15 amp circuit breaker is recommended for all Evaporator models.

3) A 15 amp dedicated circuit breaker (non GFI) is recommended for 3000S/Sh and 4000S/Sh Con-
densing Units

5) A 25 amp dedicated circuit breaker (non GFI) is recommended for the 8000S Condensing Unit.

4) A 20 amp dedicated circuit breaker (non GFI) is recommended for the 6000S Condensing Unit.

SINGLE 115V 60HZ POWER SUPPLY TO/FROM

EVAPORATOR