Fusing - 21TR Plus

TM

The light bar should be installed with an external fuse or circuit breaker in the RED lead of the 2 conductor 10 AWG power cable of the

21TR Plus™ bar. The recommended external fuse size for the light bar is 30A. The internal circuitry of the Central Controller is reverse

polarity protected. Each output on the Central Controller board is protected against over current and over heating with automatically

resetting output devices.

wiring - 21TR Plus

TM

Connect the black lead to a solid frame ground (earth), preferably the (-) or ground (earth) side of the battery, and the power wire to

the +12V terminal of the battery. Connect the remaining wires in the 16 conductor cable as shown in Table 3.

For the ArrowStik® function, connect the appropriate control wires to any control switch capable of providing +power at approximately

25ma current. As noted in the wire description, connecting both the LEFT Arrow and RIGHT Arrow wire to +power at the same time

enables the Center-Out ArrowStik function.

Table 3 - Control Wire Definitions - 21TR Plus

TM

Note: All control inputs are +power enabled.

Control Input Function Definition
wire Color

Function

description

GRN/BLK

Level 1

Level 1 Emergency Mode

WHT/BLK

Level 2

Level 2 Emergency Mode

RED/BLK

Level 3

Level 3 Emergency Mode

ORG/BLK

Take Down lights

Take Down Lights Steady Burn (overrides Take Down Flash)

BLU/BLK

Rear Cut-Off

Blacks-Out Rear Facing LEDs

GRN/WHT

Front Cut-Off

Blacks-Out Front Facing LEDs

RED/WHT

Right Alley Light

Right Alley Steady Burn (overrides Alley Light Flash)

BLK/WHT

Left Alley Light

Left Alley Steady Burn (overrides Alley Light Flash)

WHT

ArrowStik Flash

ArrowStik Flash (overrides L1, L2 & L3 for rear of light bar)

BLK/RED**

Pattern Select

Pattern Select for ArrowStik, L1, L2 & L3, enables test mode)

BLK

Take Down Flash

Enables Take Down Lights Wig/Wag Flash

RED*

ArrowStik Left

Left ArrowStik (overrides L1, L2 & L3 for rear of light bar)

GRN

Cruise Lights

End LEDs only (overridden by all other functions except for Dim)

ORG*

ArrowStik Right

Right ArrowStik (overrides L1, L2 & L3 for rear of light bar)

BLU

Light bar DIM

Sets LED to Dim mode

BLU/WHT

Alley Light Flash

Enables Alley Light Wig/Wag Flash

Flash Pattern Selection - 21TR Plus

TM

The Pattern Select wire is the BLK/RED wire in the 16 conductor control cable and is activated by momentarily touching the wire to

+12V. Reference Table 4 for flash patterns.

Step 1

Power-up the light bar by connecting the Red wire to +12V and the Black wire to ground, and select Level 1 on a user-purchased 3

Level controller or, if the Lightbar is not yet connected to a controller, energize Level-1 by connecting the GRN/BLK wire in the 16

conductor control cable to +12V.

Step 2

Observe the flashing pattern operation and determine which pattern is in operation for Level-1. Refer to Table 1. This table shows the

available flash patterns. Note: the Factory Default is different and identified in the table for each of the flash mode Levels (L1, L2, L3).
Once the flash pattern has been determined, proceed to Step 3.

This Product contains high intensity LED devices. To prevent eye damage, DO NOT

stare into light beam at close range.