Arrowstik, Pattern selection – Code 3 21TR & 21TR Plus User Manual

Page 12

Advertising
background image

12

ArrowStik®

Pattern Selection

The 21TR Plus™ is designed to offer user selectable traffic directing signals and traffic warning options.

This allows the greatest flexibility when controlling the various configurations available. The end user can match the desired sig-

nal to a particular light bar configuration whether it is a 5, 6, 7, or 8 light head configuration. The light bar will come from the fac-

tory with the Building Fast default pattern for the ArrowStik configuration you ordered. If it is desired to change the pattern in any

of the modes (LEFT, CTR, RIGHT or FLASH) follow the programming procedure outlined. Reference Table 5 for flash patterns.

LEFT

CENTER-OUT

RIGHT

FLASH

1. Building 8HD

2. Building 8HD, 3 Flash

3. Travelling Ball 8HD, 3 Flash

4. Build/Collapse 8HD

Building 8HD

Building 8HD, 3 Flash

Travelling Ball 8HD, 3 Flash

Build/Collapse 8HD

Building 8HD

Building 8HD, 3 Flash

Travelling Ball 8HD, 3 Flash

Build/Collapse 8HD

Quad Fl Even/Odd

Left/Right Flash *

Quad Fl, Left/Right

Travelling Ball Flash

5. Building 7HD

6. Building 7HD, 3 Flash

7. Travelling Ball 7HD, 3 Flash

8. Build/Collapse 7HD

Building 7HD

Building 7HD, 3 Flash

Travelling Ball 7HD, 3 Flash

Build/Collapse 7HD

Building 7HD

Building 7HD, 3 Flash

Travelling Ball 7HD, 3 Flash

Build/Collapse 7HD

Standard Flash *

Quad Flash Standard

Simultaneous Flash *

Quad Fl Simultaneous

9. Building 6HD

10. Building 6HD, 3 Flash

11. Travelling Ball 6HD, 3 Flash

12. Build/Collapse 6HD

Building 6HD

Building 6HD, 3 Flash

Travelling Ball 6HD, 3 Flash

Build/Collapse 6HD

Building 6HD

Building 6HD, 3 Flash

Travelling Ball 6HD, 3 Flash

Build/Collapse 6HD

Even/Odd Flash*

13. Building 5HD

14. Building 5HD, 3 Flash

15. Travelling Ball 5HD, 3 Flash

16. Build/Collapse 5HD

Building 5HD

Building 5HD, 3 Flash

Travelling Ball 5HD, 3 Flash

Build/Collapse 5HD

Building 5HD

Building 5HD, 3 Flash

Travelling Ball 5HD, 3 Flash

Build/Collapse 5HD

Table 5 - Traffic Directing / Traffic Warning Pattern Options - 21TR Plus

TM

Signal Options for ArrowStik® Control

As mentioned previously, the 21TR Plus

TM

will come from the factory with the ArrowStik patterns set in the default configuration,

which is the Building Fast configuration. The current configuration can be determined by observing the operation of the ArrowStik

unit. Note that FLASH Signal Patterns marked with an Asterisk "*" are available in Fast, Medium or Slow flash rate.

Note: It will be important to observe the operation of the ArrowStik unit during the programming procedure while stepping

through the signal options. Signals are available for 5, 6, 7, or 8 head configurations. Also refer to the traffic directing

signal options in Table 2 for the following procedure.

The Pattern Select wire is the BLK/RED wire in the sixteen conductor light bar control cable and is activated by momentarily touching

the wire to +12V.

Step 1

Power-up the light bar by connecting the Red wire to +12V and the Black wire to ground. Select the ArrowStik mode that you wish to

program (LEFT, CENTER-OUT, RIGHT or FLASH).

Step 2

Observe the ArrowStik operation and determine the current mode. Determine what pattern and configuration the control head is cur-

rently in, if not in the factory default. Once the pattern / configuration have been determined, proceed to Step 3.

Step 3

Refer to Table 5, above. This table shows the available patterns for each mode and their order in program memory. Notice that for

the LEFT, CENTER-OUT and RIGHT positions there are four (4) pattern choices; Building, Building with 3 Flash for the end lights,

Traveling Ball with 3 flash for the end lights and Build/Collapse, four (4) configurations for the number of heads; 5, 6, 7, or 8HD and

three (3) speeds; Fast, Medium and Slow. There are a total of twelve possible selections for each configuration of light heads and

then you return to the top selection, Building Fast. Starting from the first pattern in Table 5 you can step through each pattern, ( 1-4 )

for an 8HD, ( 5-8 ) for a 7HD, ( 9-12 ) for a 6HD, and (13-16) for a 5 HD configuration, by momentarily holding the Pattern Select wire

to +power for 1-2 seconds, until the ArrowStik light heads stop, and then releasing. This will step to the next pattern in Table 5 for the

selected mode. The new pattern is automatically stored each time.