Fusing - 21TR

TM

The light bar should be installed with an external fuse or circuit breaker in the RED lead of the 11 conductor cable. The recommended

external fuse size for the light bar is 15A. The internal circuitry of the Central Controller is reverse polarity protected. Each output on

the Central Controller board is protected against over current and over heating with automatically resetting output devices.

wiring - 21TR

TM

Connect the black lead to a solid frame ground (earth), preferably the (-) or ground (earth) side of the battery, and the power wire to

the +12V terminal of the battery. Connect the remaining wires in the 11 conductor cable as shown in Table 1.

Table 1 - Control Wire Definitions - 21TR

TM

Note: All control inputs are +power enabled.

Control Input Function Definition
wire Color

Function

description

BLUE

Level Control Wire

Energizes light heads per the pattern chosen by the end user or, if left

unchanged, per the defaults set at the factory (see Table 2).

ORANGE
YELLOW #1 (18 GA)
LIGHT BLUE

Take Down lights

Take Down Lights Steady Burn (overrides Take Down Flash)

YELLOW #2 (20 GA)

******Not Used******

******Not Used******

YELLOW/BLACK

Left Alley Light

Left Alley Steady Burn (overrides Alley Light Flash)

WHITE

Light Bar Dimming

Dims All Lighthead Modules in Lightbar Except for Corners

GREEN

Pattern Select

Light Bar Flash Pattern Select Wire & Diagnostic Test

BLACK

Ground

Ground

RED

Power

+12V Input Supply

BROWN

Right Alley Light

Right Alley Steady Burn (overrides Alley Light Flash)

Flash Pattern Selection - 21TR

TM

The Pattern Select wire is the Green wire in the 11 conductor control cable and is activated by momentarily touching the wire to +12V.

There are seven total combinations of unique flash patterns that can be defined with a unique flash pattern. It is also impor-

tant to understand whether the light bar will be controlled by a progressive style switching controller, or individual switches.

This often leads to confusion in selecting patterns and may result in the end user not achieving the desired outcome. This is

discussed in the section titled "Progressive vs. Independent Switching".

diagnostic Test

There is also a diagnostic test that can be run using the Green pattern change wire. Apply +12V to the Green wire (only). The lights

will turn on one at a time and then turn off. At the end it should flash all emergency lights at the same time three times. Note that

it can only be activated by applying power to the Green wire at start up. If the unit has been energized with any other wire, power

needs to be removed entirely from the light bar before applying power to the Green wire to enter into this mode again.

This Product contains high intensity LED devices. To prevent eye damage, DO NOT

stare into light beam at close range.