2 creating an emulated lan, Creating an emulated lan -4 – Cabletron Systems Smart 04-0053-01 User Manual

Page 22

Advertising
background image

2-4 SmartSwitch ATM User Guide

Creating an Emulated LAN

IP Over ATM and LANE

2.2

CREATING AN EMULATED LAN

This section describes the steps for implementing an Emulated LAN (ELAN) on your SmartSwitch ATM switch.

Note

If LANE services are to be reached through a virtual port on an ATM
SmartSwitch, this switch must be a SmartSwitch 6500. Only the SmartSwitch
6500 supports logical multicasting. If LANE services are NOT reached through a
virtual port, LANE services can reside on any ATM SmartSwitch.

The following assumptions are made:

The ATM SmartSwitch will contain a client on the ELAN

All end nodes (computers, edge devices, other switches, and so on) support the Well Known LECS
Address or the Anycast Address or can obtain the address of the LECS using ILMI

All end nodes support Switched Virtual Circuits (SVCs)

Note

An ELAN comes pre-configured on all SmartSwitch ATM switches. The ELAN
name is “ELAN000.” To use this ELAN, start the LECS, configure your end nodes
and edge devices to use ELAN name ELAN000, and then plug them into the ATM
SmartSwitch.

1.

Enter the

start lecs

command to activate LANE server services on this ATM SmartSwitch.

SmartSwitch # start lecs

NOTICE - 'LECS' ***** LECS started *****

— This assumes the LES/BUS is running (default)

SmartSwitch #

2.

Create an ELAN on your ATM SmartSwitch by executing the

add elan

command. The following

is an example.

SmartSwitch # add elan

ELANNumber(0) : 1

— 1 is used instead of the default, (0)

ELANName(ELAN001): Marketing

— ELAN is named Marketing instead of the default, (ELAN001)

ConnectMethod(SVC):

ELANType(802.3)

—The default (Ethernet) is used

Multipoint(YES) :

MTU(1516) :

ErrorLogEnable(NO) :

— Take the default

MinimumTDEnable(NO) :

— Take the default

Distribute(PROXY) :

SmartSwitch #

3.

Use the

add laneclient

command to create a client for the switch on the ELAN:

SmartSwitch # add laneclient

ClientNumber(0) :1

— One is used instead of the default, (0)

LanName(ELAN001) : Marketing

— ELAN name is Marketing, not the default, (ELAN001)

ServerType(LECS) :

ServerAddress()

— No LANE server address is specified; see note below

IPAddress() : 90.1.1.1

— IP address and subnet mask are specified only as examples

NetMask(255.0.0.0): 255.255.255.0

MTU(1516) :

SmartSwitch #

Advertising