5-16 SmartSwitch ATM User Guide

Soft PVC and PVP Connections

Virtual Ports and Static Connections

3.

Use the

add spvcaddress

command on the target switch to specify the target port and ATM address.

SmartSwitch # add spvcaddress

PortNumber() : 6b3

— Port on target switch

AtmAddress() : 22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

Added SPVC Address successfully.

SmartSwitch #

Note

Both soft PVCs and Soft PVPs use the

add spvcaddress

command to specify the

target switch’s target ATM address. There is no separate “

add spvpaddress

command.

4.

Use the

show spvcaddress

command to see the soft PVP port and ATM address on the target switch:

SmartSwitch # show spvcaddress

PortNumber(ALL) :

TargetAddress() :

Port SPVC Target Address

================================================================================

6B3 22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

Total number of SPVC Addresses = 1

SmartSwitch #

5.

On the source switch, use the

add trafficdescriptor

command to create traffic descriptors for the

forward and reverse directions of the connection (See Section 5.1.1for information about traffic
descriptors).

6.

On the source switch, use the

add spvp

command to create the soft PVP connection between the two

switches:

SmartSwitch # add spvp

PortNumber() : 7a1

— Port on source switch

SourceVpi(0) : 3

DestinationSelectType(REQUIRED) :

— See note below

DestinationVPI(0) : 3

We use VPI= 3

TargetAddress() : 22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

TransmitTrafficDescriptorIndex() : 3

ReceiveTrafficDescriptorIndex() : 3

RetryInterval(10000) :

RetryLimit(3) :

RetryThreshold(1) :

SmartSwitch #

Note

The

DestinationSelectType

determines which vpi is used on the target switch.

The possible settings are

REQUIRED

and

ANY

. If

DestinationSelectType

is set to

REQUIRED

, the specified target vpi is set at the target switch. If

ANY

is specified, the

soft PVP uses the first available vpi it finds on the target switch. If

ANY

is specified,

enter the

show spvptraget

command on the target switch to determine the vpi

used.