MODEL 416/ 426

SWITCHBOX

Read all instructions and warnings before installing and using.

INSTALLER: This manual must be delivered to the end user of this equipment.

IMPORTANT:

INSTALLATION

& OPERATION

MANUAL

Battery

2

3

4

5

6

1

32 amps 16 amps 16 amps 10 amps 10 amps 10 amps

32 amps 16 amps 16 amps

Vehicle chassis (earth)

18 ga. black wire

when mounted in hot environments or

operated close to their capacity. Do not use

1/4" dia. glass fuses as they are not suitable

for continuous duty in sizes above 15 amps.

4) Connect the black wire to vehicle chassis

(earth).

Larger wires and tight connections (crimp

connectors perform poorly over time) will

provide longer service life for components. It

is highly recommended that terminal blocks

or soldered connections be used with shrink

tubing to protect the connections. Do not use

insulation displacement connectors (e.g. 3M®

Scotchlock type connectors). Route wiring

using grommets and sealant when passing

through compartment walls. Minimize the

number of splices to reduce voltage drop.

High ambient temperatures (e.g. under hood)

will significantly reduce the current carrying

capacity of wires, fuses, and circuit breakers.

Use "SXL" type wire in engine compartments.

416 Switchbox

16 ga.

orange

16 ga.

blue

14 ga.

white

10 ga.

red/ black

16 ga.

yellow/

black

14 ga.

purple

8 ga red

input

Customer supplied

fuse (sized to 125%)

55 amps max load for entire Switchbox

Vehicle chassis (earth)

18 ga. black wire

Customer supplied

fuse (sized to 125%)

(+) 12 Volt ignition circuit

white/ black wire

Panel backlighting

8 ga red input

Battery

32 amps 16 amps 16 amps 10 amps 10 amps 10 amps

32 amps

16 amps

16 amps

55 amps max load for entire Switchbox

20 amp

breaker

40 amp

breaker

20 amp

breaker

16 ga.

yellow/

black

16 ga.

orange

16 ga.

blue

14 ga.

purple

14 ga.

white

10 ga.

red/ black

3

2

1

5

6

4

Introduction

The 416 Switchbox is a 6 switch control center

without circuit breakers. The model 426 is the same

6 switch control center protected by 3 circuit breakers.

The 426 also offers backlighting as standard

equipment. Backlighting is optional on the 416.

Procedure

Wiring Instructions:

1) The installer needs to first determine the

current load in amps of each of the devices

to be switched by the Switchbox.

2) Connect the devices to the desired switch,

noting the current limitations of each switch

and group of switches.

3) An 8 gauge wire should be run from the

Red 8 gauge Switchbox input wire to a

user supplied fuse, then to the (+) side of

the battery, the alternator, or the stud on

the battery side of the solenoid. The user

supplied fuse should be located as close

to the battery as possible and sized to

125% of the total load carried by the

Switchbox (i.e.: if the total load carried is

40 amps; 40 amps x 125% = 50 amp fuse).

A circuit breaker is not recommended

here, they are very sensitive to high

ambient temperatures and will false trip