Lighting Controls (For L4 Models Only)

WARNING LIGHTS 3-LEVEL PROGRESSIVE SLIDE SWITCH:

POSITION 1 - Supplies power to Lighting Level 1. Illuminates Green LED. Activates LightAlert if supplied

POSITON 2 - Supplies power to Lighting Levels 1 & 2. Illuminates Green and Yellow LED's. Activates LightAlert and SirenLock op-

tions if supplied.

Position 3- Supplies power to Lighting Levels 1,2, & 3. Illuminates Green, Yellow, AND Red LED's. Activates LightAlert and SirenLock

if supplied.

Auxiliary Switches:

AUXILIARY SWITCH "A" - Supplies power to the load connected to terminal SW A.

AUXILIARY SWITCH "B" - Supplies power to the load connected to terminal SW B.

AUXILIARY SWITCH "C" - Operates circuit connected to terminals SWC NO, SWC NC, SWC COM.

Functions as a latching or momentary output, depending on the type of switch installed.

AUXILIARY SWITCH "D" - Supplies power to the load connected to terminal SW D.

SirenLock - The SirenLock option, when not defeated by means of the internal switches, allows siren tones (Wail, Yelp, and Hi-Lo) to

be produced only when the Warning Light Switch is in the Lighting Level 2 (Green and Yellow LED's) or Lighting Level 3 (Green, Yel-
low, and Red LED's) position. Air Horn, Radio Rebroadcast, and Public Address are unaffected by this option.