A. SUPPLY FUSE OPEN

B. SIREN TERMINAL NEGATIVE NOT

GROUNDED

A. REPLACE FUSE.

B. RECONNECT TERMINAL

NEGATIVE TO GROUND.

PROBLEM

PROBABLE CAUSE

REMEDY

A. MAXIMUM RADIO REBROADCAST TRIM-

MER MIS-ADJUSTED

B. RRB WIRES NOT CONNECTED TO TWO-

WAY RADIO EXTERNAL SPEAKER

RRB VOLUME LOW, OR NO

RRB AT ALL. VOLUME CON-

TROL FULLY CLOCKWISE.

A. REFER TO SET-UP AND

ADJUSTMENT SECTION

B. CHECK RRB CONNEC-

TIONS

A. REMOTE SWITCH (HORN RING) WIRING

FROM TERMINAL REMOTE SHORTING TO

POSITIVE OR TO GROUND (EARTH).

SIREN SOUNDS BY ITSELF

A. CHECK WIRING FOR

ANY SHORTING.

A. VEHICLE CIRCUIT BREAKERS NOT RAT-

ED PROPERLY, AND ARE OVERHEATING,

OR ARE NOT FUNCTIONING PROPERLY

A. REFER TO SPECIFICA-

TIONS SECTION, PAGE 18.

USE A BREAKER WITH 1.25x

THE AMPERAGE RATING

FOR THE WATTAGE BEING

USED.

POWER DISTRIBUTION SEC-

TION NOT WORKING

SIREN RUNS PROPERLY

BUT SHUTS DOWN WHILE

RUNNING, THEN STARTS

RUNNING AGAIN AFTER A

FEW MINUTES