16

A. REPLACE MICROPHONE

B. PLUG MICROPHONE IN

SECURELY

C. CHECK WIRING

D. CALL PSE FOR LIST OF

ADAPTABLE MICROPHONES

PROBLEM

PROBABLE CAUSE

REMEDY

NO SIREN OUTPUT.

EXTERNAL 20A

FUSE BLOWS.

A. AMPLIFIER POWER WIRES REVERSED

POLARITY

NO OUTPUT FROM

SPEAKER, TONES

HEARD INSIDE

AMP. MODULE.

A. SPEAKER NOT CONNECTED/ OPEN

CIRCUIT IN SPEAKER WIRING

B. DEFECTIVE SPEAKERS

SIREN TONES

VOLUME TOO

LOW/GARBLED.

A. LOW VOLTAGE TO SIREN AMPLIFIER

B. HIGH RESISTANCE IN WIRING/DEFEC-

TIVE SPEAKER

C. SPEAKERS PHASED IMPROPERLY

A. CHECK CONNECTIONS

A. CHECK POLARITY

B. REPLACE SPEAKER(S)

A. CHECK SPEAKER WIRING

B. REPLACE SPEAKER(S)

A. CHECK WIRING FOR BAD

CONNECTIONS/ CHECK VE-

HICLE CHARGING SYSTEM

B. CHECK SPEAKER(S) WIR-

ING/REPLACE SPEAKER(S)

C. REFER TO PAGE 5 FOR

PROPER PHASING

HIGH RATE OF

SPEAKER FAILURE.

A. VEHICLE BATTERY VOLTAGE TOO HIGH

B. 58 WATT SPEAKER CONNECTED TO 100

WATT TERMINAL.

A. CHECK VEHICLE CHARG-

ING SYSTEM

B. USE CORRECT SPEAKER

C. CHECK TERMINALS

SIREN CONTINUES

TO OPERATE FOR

7 SEC. AFTER

MANUAL BUTTON/

HORN RING IS RELEASED.

A. "HIT-N-GO" FEATURE ENGAGED. NOR-

MAL OPERATION

INTERCLEAR WILL NOT

POWER AUXILIARY DE-

VICES.

A. THERE IS A SHORT IN THE WIRING, OR

THE LOAD IS GREATER THAN 1 A.

A. CHECK FOR SHORTS. IN-

STALL INTERCLEAR BOOST-

ER KIT (PART #INTBS)

P.A. VOLUME LOW OR NO

P.A. AT ALL. VOLUME CON-

TROL FULLY CLOCKWISE.

A. DEFECTIVE MICROPHONE

B. MICROPHONE NOT COMPLETELY

PLUGGED IN.

C. COMMON MICROPHONE CIRCUIT NOT

PROPERLY WIRED.

D. INCORRECT MICROPHONE.

TROUBLESHOOTING

(Refer to wiring diagram page 20)

A. SHORTED SPEAKER OR SPEAKER

WIRES. SIREN IN OVER CURRENT PRO-

TECTION MODE.

Advertising