Code 3 Z3 Siren Installation & Operation Manual User Manual

Page 16

Advertising
background image

16

Siren Section:

Input Voltage

10 to 16 VDC and ground - 12V units

(Note: Operation of 12V units above 15 VDC for an extended period of time may result in speaker damage.)

Operating Current 100W: 8 Amps @ 13.6V with 11-ohm load (100 Watt Speaker) - 12V units

200W: 14 Amps @ 13.6V with 5.5-ohm load (2-100 Watt Speakers) - 12V units

(NOTE: There is no 58 Watt speaker connection available.)

Standby Current

Ignition On < 10mA

Ignition Off < 1mA

Cycle Rate

Wail - 11 cycles/minute

Yelp - 200 cycles/minute

Voltage Output

~ 66 Vpp

Audio Section:

Audio Response

3 dB down points - 500 to 3000 Hz

1000 Hz, 0 dB reference

Warning Light Control:

3-Level Switch, 4 Outputs, 50 Amps maximum combined total

Level 1 & 2:

15 Amp Maximum Each Level

25 Amp Maximum Total

Green (1) & Yellow (2) LED Indication

Level 3A & 3B:

15 Amp Maximum Each Level

25 Amp Maximum Total

Red (3) LED Indication

AUX A thru D:

5 Amp Maximum Each Aux

20 Amp Maximum Total

AUX E thru H:

10 Amp Maximum Each Aux

30 Amp Maximum Total

ArrowStik:

8 Output (not internally fused), Ground Switching, 5A Per Output

DIM Output, +12VDC, 1.5A Internally Protected

System - Weight:

Amplifi er

4.2 lbs (1.9 Kg)

Control Head &

1.1 lbs (0.5 Kg)

Microphone

Boxed Unit

9.5 lbs (4.3 Kg)

Size:

Amplifi er

9.750”L x 6.832”W x 3.936”H

Control Head

6.80”L x 3.30”H x 1.07”D (Switch will increase depth dimension to 1.95”D.)

Temperature:

-22F thru +149F (-30C thru +65C) SAE Equipment Type EVS1

Advertising