Fa ct or y settings – Code 3 Z3 Siren Installation & Operation Manual User Manual

Page 7

Advertising
background image

7

FA

CT

OR

Y

SETTINGS

Setting 1

Setting 2

Setting 3

Setting 4

Setting 5

Setting 6

3-Level Switch

Function = Progressive

Level 1

Function Enabled

Horn Ring

T

ransfer = Not

A

ctivated

A

ctivate

A

rrowStik = None

A

ctivate

A

uxiliary Switch = None

Level 2

Function Enabled

Horn Ring

T

ransfer =

A

ctivated

A

ctivate

A

rrowStik = None

A

ctivate

A

uxiliary Switch = None

Level 3

Function Enabled

Horn Ring

T

ransfer =

A

ctivated

A

ctivate

A

rrowStik = None

A

ctivate

A

uxiliary Switch = None

A

rrowStik

Conventional

A

rrowStik = None

LEFT

Function Enabled

CENTER

Function Enabled

RIGHT

Function Enabled

FL

A

SH

Function Enabled

DIM

No Confi

guration

A

vailable

Horn Ring

Enable = With Horn Ring

T

ransfer

Siren

A

ctive = Hit-N-Go

Hands-Free = Scroll

Polarity = Ground

Siren Inactive = None

Park Kill

3-Level Switch Control = Level 3

A

Standby

Siren Control = Siren Standby

A

uxiliary Switch Control = No Impact

Polarity = Ground

Light

A

lert

3-Level Switch =

A

ll

A

uxiliary Switches =

A

ll

A

rrowStik =

A

ll

Slee

p

Mode

Sleep Mode = Instant

C

A

T13

C

A

T13 = Disabled

Remote

Enable = With Horn Ring

T

ransfer

Siren

A

ctive = Hit-N-Go

Hands-Free = None

Polarity = Ground

Siren Inactive = None

EU Lock = Disabled

Load Management

Group 1

V

oltage Fault

Threshold = 1

1.50 V

olts

Dropout Delay = 1 Minute

3-Level Switch = Of

f

A

uxiliary Push-Buttons = Of

f

A

rrowStik = Of

f

LoadMGR = Of

f

Group 2

V

oltage Fault

Threshold = 1

1.00 V

olts

Dropout Delay = 1 Minute

3-Level Switch = Of

f

A

uxiliary Push-Buttons = Of

f

A

rrowStik = Of

f

LoadMGR = Of

f

Group 3

V

oltage Fault

Threshold = 10.50 V

olts

Dropout Delay = 1 Minute

3-Level Switch = Of

f

A

uxiliary Push-Buttons = Of

f

A

rrowStik = Of

f

LoadMGR = Of

f

Overvoltage Protection

Enabled

SirenLock

Function Disabled

Other Push-Button Settings

W

A

IL

Primary

Tone = W

ail

Override

Tone =

Y

elp

A

ctivates = No

A

ux

Level 3 (Red)

YELP

Primary

Tone =

Y

elp

Override

Tone = Hyper-Y

elp 1

A

ctivates = No

A

ux

Level 3 (Red)

A

LT

T

ONE

Primary

Tone = Hi-Lo 1

Override

Tone = Hyper-Lo 1

A

ctivates = No

A

ux

Level 3 (Red)

M

A

NU

A

L

Siren

A

ctive = Manual W

ail

Hands-Free = Manual W

ail

Siren Inactive = Manual W

ail, No

A

UX

A

ctivated, Level 3 (Red)

A

IR HORN

Enable =

A

lways Enabled

Primary

Tone =

A

ir Horn 1

A

UX

A

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux

A

Disabled with ignition = Of

f

A

UX B

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux B

Disabled with ignition = Of

f

A

UX C

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux C

Disabled with ignition = Of

f

A

UX D

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux D

Disabled with ignition = Of

f

A

UX E

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux E

Disabled with ignition = Of

f

A

UX F

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux F

Disabled with ignition = Of

f

A

UX G

Function Enabled

Function = 8 Sec

T

imed

A

ctivates =

A

ux G

Polarity = Positive

Disabled with ignition = Of

f

A

UX H

Function Enabled

Function =

Toggle On/Of

f

A

ctivates =

A

ux H

Polarity = Positive

Disabled with ignition = Of

f

Advertising