21

F

ILLING

THE

A

IR

M

OTOR

L

UBRICATOR

Check the air motor lubricator once per month and fill as necessary.
1

Disconnect the air before removing the lubricator bowl.

2

Shut off or disconnect the air supply to the dyno, and follow lock out procedure.

3

Press and hold the dyno in or out movement switch until you cannot hear any air
going through the movement motor.

4

Before running the Gast Air Motor, remove the lubricator bowl and fill the bowl
with oil.
Note: Use a non-detergent SAE #10 automotive engine oil (Gast Part #AD220).

Figure 18: 424x Dyno—Filling the Air Motor Lubricator

AD0195

remove bowl and

fill to line with oil