STEP #9 INSTALLING GLASS STOPS

STEP #8 CLEANING THE GLAZING TRACK

FIGURE #8

3.

2.

1.

FIGURE #9

STEP #7 SETTING BLOCKS APPLICATION

SECTION VII: GLAZING AND REGLAZING DOORS

PAGE 10

The glass stops are designed to be inserted into the glazing tabs in the door rails and then

rotated down to lock into place. See Figure #9. Use a soft faced mallet, if needed. Hit on

the corner of the glass stop, making sure not to distort the metal. Start at one end and
work toward the other end of the glass stop.

Check to ensure that the glazing surface of the door and glazing bead are free from metal
shavings. Metal shavings may be blown out with air or brushed out. See Figure #9.

Insert three (3) setting blocks (#H348 or #H159) at approximately 6" from the inside

corners. Setting blocks are used at the door stiles and the bottom rail only. An adjustable

jack screw will be used at the top rail. Refer to Figure #1 on page 8. If required, apply

silicone to the back of the setting blocks to keep them in the correct position until the
glass is installed. See Figure #8.

LOCK STILE

6"

DPS/BB JULY 2000

6"

GLAZING

TRACK

PIVOT EDGE

SETTING

BLOCK

ADJUSTABLE
JACK SCREW