0 specifications, Operational specifications – ETS-Lindgren 3301C Active Monopole User Manual

Page 19

Advertising
background image

3.0 Specifications

Operational Specifications

Frequency Range:

30 Hz to 50 MHz
(maximum usable bandwidth)

Low Frequency Roll Off:

The low frequency roll off is
switch-selectable to be 3 dB down at
22 kHz, 1.9 kHz, or 170 Hz.

High Frequency Roll Off:

Antenna factor is 3 dB down at 30 MHz

Antenna Factor:

• See data chart on page 54.

• Unless otherwise noted, the low

frequency roll off is set at the 170 Hz
3 dB roll off point

Saturation Level:

• 0.8 V/m narrowband without attenuation

• 25 V/m with 30 dB of internal attenuation

selected

• 63 dBuV/m/MHz broadband saturation

level

Minimum Discernible

Signal:

• See data chart on page 56.

• For best sensitivity all internal

attenuation should be turned off

Dynamic Range:

• 111 dB at mid-band (1 MHz)

• 141 dB with the use of the internal

attenuators

Specifications