Cp372 introduction – Kontron CP372 User Manual

Page 27

Advertising
background image

CP372

Introduction

ID 25780, Rev. 01

© 2002 Kontron Modular Computers GmbH

Page 1 - 11

25780

.01.VC.021

121/1

11237

P R E L I M I N A R Y

Note:

BEST CASE ACCURACY:

best case calibration (not supported by Kontron)

ACCURACY:

calibration by Kontron (at delivery)

Table 1-5: CP372 Accuracy

OUTPUT

SIGNAL

-

TYPE

and

RANGE

SIGNAL ACCURACY

at 23°C

± % of

FULL SCALE

ACCUMULATING

DEVIATION

% per K

(S and E1 BOARDS)

ACCUMULATING

DEVIATION

% per K

(E2 BOARDS)

BEST CASE ACCURACY

0 V –

5 V

0.05

0.001

0.001

0 V – 10 V

0.05

0.001

0.001

- 5 V – + 5 V

0.05

0.001

0.001

- 10 V – + 10 V

0.05

0.001

0.001

0 mA – 20 mA

0.1

0.002

0.002

ACCURACY

0 V –

5 V

0.05

0.001

0.001

0 V – 10 V

0.075

0.001

0.001

- 5 V – + 5 V

0.075

0.001

0.001

- 10 V – + 10 V

0.1

0.001

0.001

0 mA – 20 mA

0.1

0.002

0.002

Advertising