4 external cluster enable/disable, External cluster enable/disable - 7, Cp372 – Kontron CP372 User Manual

Page 53: Con 2, Cp372 configuration

Advertising
background image

CP372

Configuration

ID 25780, Rev. 01

© 2002 Kontron Modular Computers GmbH

Page 4 - 7

25780

.01.VC.021

121/1

11238

P R E L I M I N A R Y

4.2.4

External Cluster Enable/Disable

The CP372 provides two possibilities to enable or disable all the outputs of an entire cluster at
one time. Each individual cluster may be controlled either per software or hardware, whereby
the hardware control has priority over the software control. Information regarding the software
control is provided with the driver software. The hardware control capability is described as fol-
lows.

To make use of the hardware control capability the application must provide some form of ex-
ternal switching capabilty. Figure 4-3 provides basic information for configuring an external
switch. Upon power up of the CP372, the output of each cluster is disabled until such time as
the application software requests an output of the cluster. After cluster output is enabled, it can
still be controlled by external switching. This feature permits external intervention either auto-
matically or manually at any time independent of the applicaton software.

Figure 4-4: External Cluster Enable/Disable

analog ground

R

load

R

load

R

load

R

load

S

off

S 1

S 2

S 3

S 4

off

Ch 0

Ch 1

Ch 2

Ch 3

CON 2

CP372

Example for Cluster A

(AGND)

Advertising