Environmental

Conditions

Operating:
0°C – 55°C operating temperature (forced cooling). It is the customer’s responsibility

to provide sufficient airflow around each of the components to keep them within

allowed temperature range. Note: KTQ45 operating temperature range is 0°C – 60°C

(forced cooling) but CPU cooling limitations typically lowers the maximum

temperature to 55ºC.

10% - 90% relative humidity (non-condensing)
Storage:
-20°C – 70°C

5% - 95% relative humidity (non-condensing)

Electro Static Discharge (ESD) / Radiated Emissions (EMI):

All Peripheral interfaces intended for connection to external equipment are ESD/ EMI

protected.

EN 61000-4-2:2000 ESD Immunity

EN55022:1998 class B Generic Emission Standard.


Safety:

IEC 60950-1: 2005, 2

nd

edition

UL 60950-1

CSA C22.2 No. 60950-1

Product Category: Information Technology Equipment Including Electrical Business

Equipment

Product Category CCN: NWGQ2, NWGQ8

File number: E194252


Theoretical MTBF:

449.463 / 226.855 hours @ 40ºC / 60ºC for the KTQ45/Flex

352.559 / 174.306 hours @ 40ºC / 60ºC for the KTQ45/ATXE

Restriction of Hazardous Substances (RoHS):

All boards in the KTQ45 family are RoHS compliant.

Capacitor utilization:

No Tantalum capacitors on board

Only Japanese brand Solid capacitors rated for 100degrees Celsius used on board

Battery

Exchangeable 3.0V Lithium battery for onboard Real Time Clock and CMOS RAM.
Manufacturer Panasonic / Part-number CR-2032L/BN, CR2032N/BN or CR-

2032L/BE.
Approximate 4-5 years retention.
Current draw is 5-6µA when PSU is disconnected.

CAUTION: Danger of explosion if the battery is incorrectly replaced. Replace

only with the same or equivalent type recommended by the manufacturer.

Dispose of used batteries according to the manufacturer’s instructions.