System specification – Kontron KTQ67-FLEX MED User Manual

Page 13

Advertising
background image

KTQ67/Flex -Medical Users Guide

KTD-N0849-D Page 13

Environmental
Conditions

Operating:

0

°C – 60°C operating temperature (forced cooling). It is the customer’s

responsibility to provide sufficient airflow around each of the components to keep
them within allowed temperature range.

10% - 90% relative humidity (non-condensing)

Operating altitude: up to 2000 meters

Storage:

-20

°C – 70°C; lower limit of storage temperature is defined by specification

restriction of on-board CR2032 battery. Board with battery has been verified for
storage temperature down to -40°C by Kontron.

5% - 95% relative humidity (non-condensing)

Electro Static Discharge (ESD) / Radiated Emissions (EMI):
(Pending)
All Peripheral interfaces intended for connection to external equipment are ESD/
EMI protected.
EN 61000-4-2:2000 ESD Immunity
EN55022:1998 class B Generic Emission Standard.

Safety:
IEC 60950-1: 2005, 2

nd

Edition

UL 60950-1
CSA C22.2 No. 60950-1
Product Category: Information Technology Equipment Including Electrical
Business Equipment
Product Category CCN: NWGQ2, NWGQ8
File number: E194252

Theoretical MTBF:
211.994 / 100.475 hours @ 40ºC / 60ºC for the KTQ67/Flex

Restriction of Hazardous Substances (RoHS):
The KTQ67 is RoHS compliant.

Capacitor utilization:
No Tantalum capacitors on board
Only Japanese brand Solid capacitors rated for 100 ºC used on board