3 technical specifications, General, Amc leds – Kontron AM4311 User Manual
Page 20: Operating voltages, Operation power, Temperature, Humidity, Altitude
Introduction
Page 5
AM4311 User Guide
1.3
Technical Specifications
1.3.1
General
• Mechanical:
Single, Mid-size AMC form factor
• Dimensions:
180.6 mm x 73.5 mm
• Board Weight:
100 g
1.3.2
AMC LEDs
• LED0 (blue)
Ready for Hot Swap
• LED1 (red/green/yellow)
Out of Service LED
• LED2 (green/amber/red)
Healthy LED
1.3.3
Operating Voltages
• Management:
3.0V/3.6V
• Payload:
10VDC to 14VDC
1.3.4
Operation Power
• Management
0.5W
• Payload
4.0W max.
1.3.5
Temperature
This board is designed for operation from 0 °C to 60°C inlet air temperature.
• Air Flow:
20 CFM
• Operating:
0 °C to +60 °C
• Non-Operating:
-40 °C to +85 °C
1.3.6
Humidity
The board is designed to meet Bellcore GR63, Section 4.1
• Operating:
15%-90% (non-condensing) at 0°C to 55°C
• Non-Operating:
5%-95% (non-condensing) at -40°C to 70°C
1.3.7
Altitude
The board is designed to meet the following requirements:
• Operating:
4000 m (13123 ft), may require additional cooling above
1800m (5905ft)
• Non-Operating:
15000 m (49212 ft)