Configuring port settings, 4 oem get sfp data, 3 configuring port settings – Kontron AM4311 User Manual
Page 41
Functional Description
Page 26
AM4311 User Guide
2.5.2.4
OEM Get SFP Data
Example:
Module in AMC bay B1 (IPMB-L address 0x7a), ipmitool invokes on carrier (AT8404)
ipmitool -t 0x7a -b 7 -l 3 raw 0x30 0xa0 0xac 0xce 0xca 0xcf 0xcf <ID><OFFSET><COUNT>
2.5.3
Configuring Port Settings
The port settings can be configured using the ipmitool on Kontron ATCA AMC carrier board
ipmitool <IPMB-ADDRESS> <IPMB-CHANNEL> raw <NETFN> <CMD-ID> [CMD-DATA]
IPMB-ADDRESSES:
AMC slot A1: 0x72
AMC slot A2: 0x74
AMC slot A3: 0x76
AMC slot A4: 0x78
Command Name
NetFn
LUN
Command Number
CmdGetSfpData
30h
Byte Num
Data Field
Request Data
1
Pass Code 0: ~’S’
2
Pass Code 1: ~’1’
3
Pass Code 2: ~’5’
4
Pass Code 3: ~’0’
5
Pass Code 4: ~’0’
6
0 – SFP#1
1 – SFP#2
2 – SFP#3
3 – SFP#4
7
Offset
8
Count
Response Data
1
Completion Code
D5h – when payload is not applied
CEh – when SFP is not present
C9h – when maximum count is exceeded, or when invalid SFP ID
2
Count n returned DATA bytes
3 ....
n DATA bytes