Configuring port settings, 4 oem get sfp data, 3 configuring port settings – Kontron AM4311 User Manual

Page 41

Advertising
background image

Functional Description

Page 26

AM4311 User Guide

2.5.2.4

OEM Get SFP Data

Example:

Module in AMC bay B1 (IPMB-L address 0x7a), ipmitool invokes on carrier (AT8404)

ipmitool -t 0x7a -b 7 -l 3 raw 0x30 0xa0 0xac 0xce 0xca 0xcf 0xcf <ID><OFFSET><COUNT>

2.5.3

Configuring Port Settings

The port settings can be configured using the ipmitool on Kontron ATCA AMC carrier board

ipmitool <IPMB-ADDRESS> <IPMB-CHANNEL> raw <NETFN> <CMD-ID> [CMD-DATA]

IPMB-ADDRESSES:

AMC slot A1: 0x72
AMC slot A2: 0x74
AMC slot A3: 0x76
AMC slot A4: 0x78

Command Name

NetFn

LUN

Command Number

CmdGetSfpData

30h

Byte Num

Data Field

Request Data

1

Pass Code 0: ~’S’

2

Pass Code 1: ~’1’

3

Pass Code 2: ~’5’

4

Pass Code 3: ~’0’

5

Pass Code 4: ~’0’

6

0 – SFP#1
1 – SFP#2
2 – SFP#3
3 – SFP#4

7

Offset

8

Count

Response Data

1

Completion Code
D5h – when payload is not applied
CEh – when SFP is not present
C9h – when maximum count is exceeded, or when invalid SFP ID

2

Count n returned DATA bytes

3 ....

n DATA bytes