Lpc sio configuration, Come-chl6 / bios operation – Kontron COMe-cHL6 User Manual
Page 99
COMe-cHL6 / BIOS Operation
LPC SIO Configuration
This setup option is only available with LPC SuperI/O Nuvoton 83627 present on the carrier board. By default the COMe-
cHL6 supports the legacy interfaces of a 5V 83627HF(J) or 3.3V 83627DHG-P on external LPC. The SIO hardware monitor is
not supported in setup.
Serial Port 0
Disabled
Enabled
Enable or Disable SIO Serial Port
- Base Address
3F8
2F8
3E8
2E8
Configure Serial Port Base Address
- IRQ
3
4
5
6
7
12
Configure Serial Port IRQ
Serial Port 1
Disabled
Enabled
Enable or Disable SIO Serial Port
- Base Address
3F8
2F8
3E8
2E8
Configure Serial Port Base Address
- IRQ
3
4
5
6
7
12
Configure Serial Port IRQ
SIO Parallel Port
Disabled
Enabled
Enable or Disable SIO Parallel Port
- Device Mode
Standard Parallel Port
EPP
ECP & EPP 1.9
ECP & EPP 1.7
Configure Parallel Port Mode
- Base Address
378
278
3BC
Configure Parallel Port Base Address
99