Kontron CG1200 Carrier Grade Server User Manual

Page 53

Advertising
background image


47

Kontron CG1200 Carrier Grade Server Installation and Maintenance Guide 47

6. Route the SuperCap cable from the SuperCap module between the main fan assembly and the HDD

backplane, and then past the small U-shaped air baffle to the ROC module on the server board
(Figure 37).

Figure 37: Routing the SuperCap Cable to the ROC Module

7. Re-connect the front panel power cable and the TAM alarms cable if you moved them out of the way.

8. Re-install the PCIe fan duct assembly and connect the fan power cable to fan header 1 on the server

board.

9. Re-install the PCI riser card assembly and replace the front bezel and the chassis cover.

Re-connect any external devices and the power cord(s).