75

Kontron CG1200 Carrier Grade Server Installation and Maintenance Guide 75

5.1.3. Disconnect the PMBus connector. For the location see Figure 7.

5.2. Disconnect the 2x4 CPU 1 power connector. For the location, see Figure 7, “M”.

5.3. Disconnect the HDD backplane power connector. For the location, see Figure 58.

5.4. Disconnect any optional I/O devices connected to the auxiliary cable/dongle in the front right side

of the chassis.

5.5. Disconnect the front panel board power connector. For the location, see Figure 52, “A”.

6. Loosen the two screws that secure the PDB bracket to the chassis and save them for re-installing the

new PDB assembly. (Figure 59, “A”)

7. Gently pull the PDB and all its attached cables (not shown in this figure) out of the chassis. (“B”)