Radiance vent-free gas heater – Vermont Casting thru 3379 User Manual

Page 13

Advertising
background image

13

Radiance Vent-Free Gas Heater

20004555

Glass & Catalyst Installation

CAUTION: Air shutter must be removed
when installing glass and catalyst for
proper operation.

1. Remove left and right log bracket assembly by
unfastening the two screws which hold the burner in
place. Loosen the screw on the rear log bracket and
remove the bracket.
2. Hold the burner at the right hand side and lift to clear
the right burner leg. Then pull to the right to clear the
injectors on the left hand side.
3. Turn burner upside down and remove air shutter.
Discard air shutter. (Fig. 18)

OFF

ON

Thermostat

(Optional)

Therm

opile

Black

Black

Millivolt

Gas Valve

St124b

on/off/switch

wiring

1/11/00 djt

TP/TH

TP

TH

Thermostat

(Optional)

Therm

opile

Black

Black

Millivolt

Gas Valve

St124c

Thermostat

wiring

1/11/00 djt

TP/TH

TP

TH

On/Off Switch Wiring

Optional Thermostat Wiring

ST124b

ST124c

ST353a

injector orifice

replace

3/21/00 djt

90°

Left Burner Leg

Injector Orifices

ST353a

Fig. 19 Be sure injector orifices remain at 90° to the base.

4. Replace burner. Slide the burner in at an angle with
left side lower than the right side. Slide the left side onto
the injectors, making sure the burner leg remains at a
90° angle to the base. (Fig. 19) Lower the right hand
side down in to place. Make sure the burner is as far
left as possible and the injector shoulders are inside the
burner.

5. Replace left and right log bracket assembly, tighten
rear log bracket, and replace logs.
6. Latches provided in catalyst kit must be installed
on top of firebox. Use two phillips screws to secure in
place. (Fig. 20)

7. Slide catalyst between top plate and firebox. Allow
catalyst to “fall” into hole on top of firebox. Secure with
two screws as shown in Figure 21.

ST187

pull frame latches

11/99

Phillips

Screws

Phillips Screws

ST671

Fig. 20 Attach glass latches.

Catalyst Location

ST667

RNVOD

air shutter

converting

from NG to Lp

6/4/01 djt

Air Shutter (Remove and Discard)

Bottom of Burner Pan

ST667

Fig. 18 Remove air shutter and discard.

ST201

remove catalytic

combustor

11/99

ST201

Fig. 21 Install catalytic combustor.

Advertising
This manual is related to the following products: