Clearance requirements, Radiance vent-free gas heater, Minimum clearances to combustible materials – Vermont Casting thru 3379 User Manual

Page 5: Hearth requirements, Alcove clearances, Warning

Advertising
background image

5

Radiance Vent-Free Gas Heater

20004555

Clearance Requirements

Minimum Clearances to

Combustible Materials

Maintain clearance, (empty space), between combus-
tible materials and the heater as specified below.

Hearth Requirements

The Radiance Unvented heater must be installed on
rigid flooring. If the appliance is installed on any com-
bustible surface other than wood flooring, such as
carpet or tile, a metal or wood panel must be installed
to extend the full length and width of the unit. There are
no other hearth or floor protection requirements.

Fig. 3 Minimum mantel clearance.

FP599b

JUV

stove mantel heights

9/21/00 djt

A

B

C

D

E

V

W

X

Y

Z

Mantel

Mantel from

Ref.

Shelf Depth

Ref.

Stove Top

A

7¹⁄₂” (190mm)

V

16” (406mm)

B

6” (152mm)

W

14¹⁄₂” (368mm)

C

4¹⁄₂” (114mm)

X

13” (330mm)

D

3” (75mm)

Y

11¹⁄₂” (292mm)

E

1¹⁄₂” (38mm)

Z

10” (254mm)

ST694

Wall

ST103a

Min. Clrnc

11/12/99 djt

B

B

D

A

C

A: Maximum Alcove Depth ...............24” (609mm)
B: To Side Wall ...................................4” (101mm)
C: To Rear Wall ................................. 4” (101mm)
D: To Ceiling ...................................60” (1524mm)

Alcove Clearances

ST103a

ST101

Min. Freestanding Clrnc

4/15/99 djt

B

A

A: To Side Wall / Trim*......................... 4” (101.6mm)
B: To Rear Wall ................................... 4” (101.6mm)

ST101

Fig. 2 Minimum wall clearances.

• Do not install this heater in a bathroom or bed-

room.
• Installation of this heater must conform with local

codes or, in the absence of local codes, with the

National Fuel Gas Code, ANSI Z223.1/NFPA 54.
• This heater creates warm air currents. These

currents move heat to wall surfaces next to the

heater. Installing the heater next to vinyl or cloth

wall coverings or operating the heater where im-

purities in the air such as tobacco smoke exist,

may discolor walls.
• Do not use a blower insert, heat exchanger

insert or other accessory not approved for use

with this heater.

WARNING

Advertising