Radiance Vent-Free Gas Heater

20004555

Firebox weight / shipping

175 lbs.

The installation of your Radiance stove must conform
with local codes, or in the absence of local codes,
with the National Fuel Gas Code ANSI Z223.1/NFPA
54 - latest edition. (EXCEPTION: Do not derate this
appliance for altitude up to 4,500 feet (1,370m).
Maintain the manifold pressure at 3.5” w.c. for Natural
Gas and 11.0” w.c. for LP Gas.

Radiance RUVSODRN/RP Vent-Free

Certified to:

ANSI Z21.11.2a-2001

Unvented Heaters

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/
or ODS pilot. Monthly inspection and cleaning
is recommended for altitudes above 4,500 feet
(1,370m)
For elevations above 4,500 feet (1,370m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.

WARNING: Improper installation, adjust-
ment, alteration, service or maintenance
can cause injury or property damage. Refer
to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or the gas supplier.

Odor During Operation

Neither natural gas nor propane gas give off an odor
when burned. The nature of a vent free combustion
system, however, is such that odors may occasional-
ly be produced during heater operation when impuri-
ties exist in the immediate area. Cleaning solutions,
paint, solvents, cigarette smoke, candles, adhesives,
new carpet or textiles, etc., all can create fumes.
These fumes may mix with combustion air and can
create odor. Such odors will disappear over time,
however the condition can be alleviated by opening a
window or otherwise providing additional ventilation
to the area.

This appliance may be installed in an aftermarket*
manufactured (mobile) home, where not prohib-
ited by state or local codes.
This appliance is to be used only with the type
of gas specified on the rating plate which is at-
tached to the rear panel. This appliance is not
convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.

Gas Specifications

Max.

Min.

Input

Input

Model

Fuel Gas Control

BTU/h

BTU/h

RUVSODRN

Nat.

Millivolt

35,000

26,000

RUVSODRP

Prop

Millivolt

35,000

26,000

Inlet Minimum

5.5” w.c.

11” w.c.

Inlet Maximum

14” w.c.

14” w.c.

Manifold Pressure

3.5” w.c. 10” w.c. (MP)

11” w.c. (RP)

Gas Inlet and Manifold Pressures

Natural

LP (Propane)