Pan Handle

Illumination Button

Bubble Level

Clamp Nut

Pan Handle Clamp

Fig. 4

Operating Instructions

The operating instructions are described in six steps. Please
read and understand these instructions before using this
equipment. Do not omit any steps.

The Cineline 70 Fluid Head can be mounted on a 150mm
TRIPOD BOWL or on a MITCHELL BASE.

1 Fluid Head Set-up (Mitchell Base)

1.1 Loosen the PAN HANDLE CLAMP fully then rotate the

PAN HANDLE until it is approximately perpendicular to the
THREADED STUD (fig. 1) and tighten the PAN HANDLE
CLAMP - avoid contact wear between the serrations
on the Fluid Head and the PAN HANDLE CLAMP, if this
occurs then unwind the PAN HANDLE CLAMP further.

1.2

Attach the MITCHELL BASE ADAPTOR (#1225) to the
CLAW BALL, as shown, and tighten the three M5 screws
using a 4mm Hex Key.

1.3 Ensure that the TRIPOD is level, adjust the TRIPOD if

necessary, such that the bubble is inside the black circle
(fig. 5).

1.4 Place the LOCATION BOSS into one of the three LOCATION

SLOTS and tighten the CLAMP NUT.

1.5 Set the initial control settings as follows – see Figure 1 & 2:

 Select Counterbalance to position 8 (top setting).

 Select Pan & Tilt Drag to position 0.

 Tighten the PAN LOCK and TILT LOCK.