04_cw-250, Cw-250 fabrication, Figure 1 figure 2 – Oldcastle BuildingEnvelope Solar Shelf User Manual

Page 4

Advertising
background image

4






S U N C O N T R O L - I N S T A L L A T I O N M A N U A L

SOLAR SHELF

CW-250 FABRICATION

C

FIGURE 1

FIGURE 2

Centerline of

Sunshade Anchor

Notch top of lower cap

and bottom of upper cap

as shown.

134"

134

"

SYM

134"

7

8

"

134"

134

"

Drill 5/16" dia. holes

(6) places

9

16"

212"

314"

1 3

32"

5

16"

Centerline of

Sunshade Anchor

1.1 Fabrication

1) Locate the centerline of each sunshade anchor. The standard sunshade anchor for

(CW-2058) for CW-250 will require (6) six 5/16" clear holes for attachment. See FIGURE 1 for

hole locations. ( Size, locations and quantity of bolts may vary based on project requirements,

consult engineer for specific applications.)

2) Face caps must be notched to clear anchor. Face caps are cut at centerline of sunshade,

notched on ends. Notch per FIGURE 2.

Installation Notes:

1) Face cap will be notched above and

below anchor. See FIGURE 2 for

fabrication.

2) Slide cap over anchor and snap into

position.

3) Butt splice cap at centerline of anchor.

Note: CW-2 face cap shown, notch

similar for custom applications.

Advertising