Pw180-installation – Oldcastle BuildingEnvelope PW-180 User Manual

Page 6

Advertising
background image

JULY 2011

5

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

A). OBTAIN BENCH MARKS AT EACH

1.

JAMB (4’0” FROM FINISHED FLOOR)

FROM GENERAL CONTRACTOR.

B). CHECK OPENING FOR WIDTH

AND HEIGHT.

C). CHECK JAMBS FOR PLUMB.

A). LOCATE THE START OF SWITCH ON SHOP

DRAWING OR DATA SHEET. B). ESTABLISH

DIMENSION OF TRACK CENTER LINE TO LOCK

JAMB ON SHOP DRAWINGS OR DATA SHEET.

C). INSTALL FLOOR SWITCH AND TRACKS

STARTING AT THE “START OF SWITCH POINT

AND LOCK JAMB. D). SET TOP OF TRACK WITH

FINISHED FLOOR AND LEVEL WITHIN 1/8” –

USE TRANSIT OR WATER LEVEL AND

LEVELING WEDGES. E).PACK QUICK DRYING

CEMENT AROUND ALL TRACK ANCHOR

STRAPS ANDSWITCHES. F). DO NOT SET

PANELS UNTIL CEMENT IS HARD.

A). INSTALL TOP TRACK LEVEL AND

4.

PLUMB WITH BOTTOM TRACK.
B). USE A STORY POLE TO HOLD

VERTICAL OPENING DIMENSION

TO +1/4” TO –0”.

A). DOUBLE CHECK SHIP-

MENT BYLAYING OUT TRACK

2.

& ACCESSORIES IN ACCOR-

DANCE WITH ASSEMBLY

PRINT AND ACCESSORY LISTS.

B). TAILS OF TOP SWITCH

MUST FACE SAME DIRECTION

AS FLOOR SWITCH.

PRIOR TO INSTALLATION OF TAIL TRACK

3.

ATTACH STOP BY THREADING SCREW

INTO HEX NUT INSERTED INTO TRACK.

ATTACH NEOPRENE BUMPER STOP

IN OUTERMOST TRACK LANE,

SET AGAINST THE ANGLE STOP.

P W - 1 8 0 S L I D I N G M A L L F R O N T

I N S T A L L A T I O N I N S T R U C T I O N S

Advertising