1. Apply power and select power source (see above).

Details

2. Connect pack.

3. Press INC or DEC to select desired User Preset, then press ENTER.

4. For each question, press INC or DEC to select correct answer, then press

ENTER

.

5. CHECKING PACK indicates PowerLab 8 is attempting to detect attached

pack.

6. Screen displays preset’s chemistry. If this matches pack’s chemistry, press

ENTER

to start. (If they don’t match, just wait for the next prompt, then press

ENTER

to return to the User Preset menu.)

7. During the operation:

• Press

INC

or DEC to view data.

• Press

ENTER

to change charge current.

• Press and hold ENTER to stop the operation.

8. “Beep beep beep” indicates the operation is complete. Display shows

elapsed time. Press INC/DEC to review data. Operation is complete, but
“session” remains open so you can review collected data. Press and hold
ENTER

to terminate session (this erases session data).

9. Disconnect pack.



Charge,
discharge, cycle
or monitor a
pack

10. Press ENTER to return to User Preset menu.

Charge packs in
parallel

To ensure safety, only use REVOLECTRIX Safe Parallel Adapters and stackable
safety banana plugs when charging/discharging/cycling packs in parallel.
Connect up to 9 batteries of same chemistry, cell count and capacity in parallel
by stacking banana plugs. Charge as above, but enter number of packs at
Parallel Packs?

question (e.g., 2P, 3P, 4P). PowerLab 8 multiplies preset’s

current setting by the number of “P” selected.

Details


*Assumes Choose Power Source at Startup is enabled in the CCS.