Cell Voltage Monitor & Logger CellLog 8S

TYPE

XXXXXXXXXX

LOGS

0

RATE

:2.0

[2016Kb/35h:50]
Logs OFF

QUICK START


CellLog Power On Rec. Interval

(2 ways: one is connecting the battery through the left 9 Pin socket, the other one is through the USB port),
System self-check, and then shows the SN and version number, the display information are as below:

The first line is the current selected Setting Type (See
detail in P10). The second line shows the log file number.
And the third line is the available record of capacity and
time. The last line shows the current log file name (if no
files, it shows "Logs OFF"). 3 seconds later, the system
enters to voltage monitor status.


Voltage Monitor

There are 4 interface choices, which can be shifted by <▲> or <▼>buttons.
















As the left pictures: the ‘7‘ in ‖7S‖ means cell counts; ‘6H‘
means the 6

th

cell voltage is the highest; ‘1L‘ means the 1

st

cell voltage is the lowest.
If the monitor voltage trigger alarm, the corresponding
voltage and alarm display (LOW, OVER or DIFF) shows
alternatively.
The cell number and (L, O, D) shows alternatively.

LOW‘ or ‗L‘ means: Low voltage alarm
OVER‘ or ‗O‘ means: Over voltage alarm
DIFF‘ or ‗D‘ means: Voltage difference alarm. They will be

displayed at the same time at the highest and the lowest
cell voltage interface.


Monitor the pack voltage
Display respectively: Current pack voltage, Max. Pack
voltage, Min. Pack voltage, Pack voltage difference. (▣P =

HV-LV

)


Data Logging

When in Voltage Monitor status, press <▼> button for 3 seconds, after it shows ‖Start logging…‖, the
calculagraph will be shown alternatively at the upper right corner of the LCD screen. In this status, the system
will transmit the voltage data to USB port every X seconds( this interval time X can be set by user himself,
details you can see Record Interal Time Setting in P13), and save these data to the current Log file(See
Log File Management in P12. If 【Logs OFF】, the system will not log file)
Press <▼> for 3 seconds again, the screen will show ‖Stop logging!‖ and then exit.

View Logging Point

In the monitor status, press <▲> and <▼> at the same time to enter the view logging point status.
Three points voltage data can be searched:‖Starting logging…‖data, ‖Stop logging!‖ data, and the data of
voltage alarm during this period , which can be shifted by < > buttons. Press < > for 3 seconds,it will return
to the monitor status.
The saved data can be covered till next logging.
If the logging time is over the users setting safety time,(See Monitor Safety Time Setting in P11), it will
trigger Safety Time Alarm, and the screen shows ‖T_OVER‖ alternatively in the upper right corner.

Alarm configuration Name

Existent Log Files Number

Free Capacity/Free Time

Current Log File Name

1234567-

7S

28.79

6H

4.162

1L

4.013

V

149mV

Pack Voltage

The highest voltage
The lowest voltage
The maximum
voltage difference

Cell Number

Voltage

Histogram

1

4.013V

2

4.150V

3

4.110V

4

4.152V

5

4.087V

6

4.162V

7

4.120V

8

------

Cell Voltage

Cell Number

7S

28.79V

V

149mV

1

4.01

2

4.15

3

4.11

4

4.15

5

4.08

6

4.16

7

4.12

8

----

Pack Voltage

The Max. Voltage
difference

Cell Number

Cell Voltage

7S

28.79V

HV

28.80V

LV

28.78V

P

0.020V

Pack Voltage
Max. Pack Voltage
Min. Pack Voltage

Pack Voltage Difference

<▢>

<>

<▢>

<>

<▢>

<>

Record interval time