Cell Voltage Monitor & Logger CellLog 8S


Alarm Remind

If CellLog detect the alarm events (See Alarm Trigger Settings in P11), it will remind as below:
1. The buzzer beeps every 4 seconds(【Alarm Tone】is selected , See P13).
2. The corresponding individual voltage and alarm remind show alternatively.

Alarm Remind Information: ―LOW‖, ―OVER‖, ―DIFF‖, ―T_OVER‖

3. ALM port will output the presetting signal.

ALM port signal information:
ALM output port signal is open collector signal, as showed below.




Please pay attention to the port voltage and current limit when you use(<50V,<500mA)

The following are ALM Output typical application.







ALM Output

+

-

Q9

ALM

+

-

VCC

Output

Level Output

R

ALM

+

-

VCC

Output

Relay Output