3.1

Operation of Remote Switch Inputs

37

34

33

4

3

1

2

DB-37

Zero Switch

Gross/Net

Auto Tare

Hold

Units Select (primary/secondary)

or Tri-State Enable

Logic Common

Logic Common

OFF

ON

OFF

AUTO TARE

GROSS/NET

ZERO

ON

HOLD
(If on, this freezes the BCD registers)

UNITS SELECT (toggles between primary
and secondary) or TRI-STATE Output Enable
(if Tri-State configuration switch is enabled

,

On position enables Tri-State mode)

.

Figure 3-2. BCD Remote Switches

Three of the front panel switches (zero switch, gross/net switch, and auto tare switch), can be operated from a

remote location using momentary-action pushbuttons. Note that each “push” of a remote switch activates the

associated function once. The function of the gross/net switch is to change the state of output between gross and net

mode.
An alternate action switch is suggested to operate the Hold and Units Select/Tri-State Enable. When using the BCD

option in Units mode, the switch state is independent of the front panel and toggles between primary and secondary

units if any change of state is detected.
Tri-State output enable is used to allow other peripheral devices to use the same BCD output. To place the unit in

Tri-State mode, set dip switches according to Table 2-4.
All switch inputs are tied to 5V through pull-up resistors on the BCD option card to ensure reliable operation.

Note

Connect the pins/switches to Logic Common only, not case ground or other grounds.