2 dip switch configuration – Rice Lake 520 HMI Digital Weight Indicator Manual - BCD Option User Manual

Page 8

Advertising
background image

4

BCD

Interface Installation and Configuration Manual

2.2

Dip Switch Configuration

The BCD option card contains dip switches (see Figure 2-3). Move the switches to configure BCD interface

parameters (see Table 2-1).

Table 2-1. Dip Switch Configuration Modes

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

DEC_1

DEC_2

POL_SEL

Units/Com Select

Units Input Select

Tri-State Select

Reserved

Reserved

Unit Status Bit/Communications Output Selection

See

Table 2-2. Units Status Bit/Communications Select Mode Configuration

SW1-4

Mode

0

Unit Status Bit mode – Indicates primary or secondary

1

Communications Select mode – RS-232

Table 2-2 for unit status bit/communications output select configuration.

By connecting J3 on the BCD board to J8 on the 520 board, communications mode allows the throughput of

connector J3 to be used as a wiring path for communications from the 520 indicator to an external device through

the DB-37 connector. It is not a communications port, rather an alternative route for wiring a 520 communication

port to an external device.

Table 2-3. J3/J8 Connections

BCD Option Card

520 Indicator

J3-1

TX

J8-1

TX

J3-2

Gnd

J8-2

Gnd

J3-3

RX

J8-3

RX

WARNING

Do not connect communications to J3 if switch SW1-4 is in Units mode.

Units/Tri-State Input

Table 2-4. Units/Tri-State Input Configuration

SW1-5

SW1-6

Mode

0

0

Not valid

0

1

Units enable

1

0

Tri-State enable

1

1

Off

See Table 2-4 below, for information on configuring units or tri-state input modes.