0 installation, 1 bcd option card installation, Installation – Rice Lake 520 HMI Digital Weight Indicator Manual - BCD Option User Manual

Page 6

Advertising
background image

2

BCD

Interface Installation and Configuration Manual

2.0

Installation

Figure 2-1 shows the BCD option card as installed in the 520 indicator. The indicator enclosure must be open to

install the BCD card.

WARNING

The 520 has no on/off switch. Before opening the unit, ensure the power cord is disconnected from the
power outlet.

Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when
working inside the indicator enclosure.

CAUTION

These units use double pole/neutral fusing which could create an electric shock hazard. Procedures
requiring work inside the indicators must be performed by qualified service personnel only.

2.1

BCD Option Card Installation

1. Disconnect the 520 indicator from power source.
2. Place the indicator on an antistatic work mat. Remove screws that hold the backplate or cover to the

enclosure body, then lift the backplate or cover away from the enclosure and set it aside.

3. Use the 8-32 nuts in hardware kit to secure DB-37 connector plate to backplate of indicator.

BCD Option
Board

Configuration
Dip Switch

Figure 2-1. 520 Indicator with BCD Option Installed

4. Carefully align the large option card connector (J1) with connector J2 on the 520 CPU board. Press down

to seat the option card in the CPU board connector.

5. Use the 4-40 screws provided in the option kit to secure the other end of the option card to the threaded

standoffs on the 520 CPU board.

6. Plug 40-pin ribbon cable to J4 on BCD card.

WARNING

Do not connect communications to J3 if switch SW1-4 is in Units mode.

7. Plug serial cable to J3 on BCD card. Plug other end of serial cable to J8 on 520 CPU board. Use the nylon

tie in the parts kit to secure the serial cable to the mounting pem (see Figure 2-2 below).

Note

When connecting serial cable to J8 of 520 CPU board, be sure that red wire goes to TX (transmit), black wire to
GND (ground), and green wire to RX (receive).